Electrical performance of enameled winding wire

Resistance:
Take 1m of the enameled wire to be inspected, scrape off the paint film at both ends, measure the resistance of the enameled wire, the resistance measurement value should be within the resistance range of GB/T6109; the standard temperature is 20 degrees, the conversion formula: 20 degrees resistance/234.5+standard Temperature = actual measured resistance/234.5 + measured temperature;

Rated 4.5/5 based on 458 customer reviews
Share:
Content

Salt bath test:
See salt bath test standard

Breakdown voltage: take the enameled wire 0.5m and fold it once, cut the half-folded part and scrape off the four wires, and then fold it twice, twist the enameled wire into a twist state, (two ends on each end) respectively Use a high voltage meter to test the high voltage of the two wires at the same end (high voltage standard: refer to the national level 2 standard).